The term “rainfall” defines the quantities of rainwater precipitated in the first 15 minutes of the weather event; such quantities are defined in relation to a reference value which is usually 5 mm across the entire concerned surface.
This water must be separated from the “subsequent rainfall” (precipitated in the following 15 minutes) and treated before the final release, as it carries away the polluting elements present on the draining surface due to washout.
During the last decades, impervious areas, especially for productive and commercial use, have vastly increased.
For this reason, regulations have been developed that require rainwater falling on impervious surfaces to be accumulated and treated to prevent the release of sand, soil, hydrocarbons, oil residues, particles of consumables from vehicles, etc. into watercourses or public sewers.
Art. 113 of Legislative Decree 03 April 2006 n° 152 part III “Provisions on the protection of waters from pollution” states that waters must be regulated.
The EU directives n° 91/271/CEE “Urban waste-water treatment”, and n° 91/676/CEE “Meteoric runoff and first rain waters”, both acknowledged by the Italian state, state:
- In order to prevent hydraulic and environmental risks, the regions, following the opinion of the Ministry of Environment and Territorial Protection, regulate and implement:
- The control types of stormwater runoff leaks coming from separate sewer systems
- The cases when stormwater runoff leaks, which are conducted by separate tubes, are subject to special requirements, including possible authorisation.
- Rainwaters not regulated according to paragraph 1 are not subject to restrictions or prescriptions deriving from part three of this decree.
- The regions also regulate the cases when it is required that the rainfall and outdoor areas washing water are conveyed and appropriately treated by purification systems. This occurs in specific conditions when there is a risk of runoff of dangerous substances or elements from uncovered impermeable surfaces that would impede water quality standards.
- Direct rainwater draining in groundwater is forbidden in any case.
Lombardy Regional Law of 24th March 2006 n° 4, concerning the “Discipline of the disposal of rainfall waters and washing waters of external areas” in the implementation of article 52, paragraph 1, letter a) of the regional law 12th December 2003, n°26 (BURL of 28th March 2006 n° 13, 1st suppl. ord.) states:
Art. 3: Rainfall and washing waters subject to regulation.
The formation, the conveyance, the separation, the collection, the treatment, and the draining of the rainfall waters are subject to the dispositions of the present regulation in case these waters come from:
- Draining areas larger than 2,000 square metres (calculated excluding roofing and green areas) in buildings and installations where the following activities are carried out: oil industry, chemical industry, metal treatment and coating, colouring and dyeing of hides and leathers, pulp (paper and cardboard) production, tyre production, textile companies carrying out printing, dyeing and finishing of textile fibres, concrete production, intermodal areas, car repairing, coachbuilding.
- Draining areas of buildings and installations which operate waste storage, collection and processing centres, scrap yards and wrecking yards.
- Draining areas associated with the loading and distribution of fuel and related or complementary operations at service stations for motor vehicles.
- Draining surfaces specifically or even occasionally intended for the storage, loading, unloading, transfer, and general handling of the substances listed in Tables 3/A and 5 of Annex 5 of Legislative Decree No. 152, Part III of 03 April 2006.
Art. 5: Collection and conveyance systems for rainfall and washing water.
- All the surfaces mentioned in article 3 must be impermeable.
- The rainfall and the washing waters, that are to be discharged in a body of surface water or on the ground or in the superficial layers of the subsoil, must be sent to appropriate collection tanks with perfect seal, dimensioned in such a way as to hold altogether not less than 50 cubic meters per hectare of draining surface (rainfall tanks).
- The rainwater runoff must flow through a special collecting and conveying network, equipped, in the cases mentioned in subsection 2, with a refilling system of the rainfall tanks that automatically excludes them once they are full; the network must be sized on the basis of the weather events of short duration and high intensity typical of each zone, assuming that the event occurs in fifteen minutes and that the coefficient of inflow to the network is equal to 1 for the draining surface and to 0.3 for any type of permeable surfaces contiguous to them, excluding uncultivated surfaces and those of agricultural use.
Lombardy’s regulations have now been adopted by almost all Italian regions.