MB CAPI

Outdoor pre-autoclave system, MB CAPI model (compressor autoclave pump inverter) composed of a pressurised first collection tank made of hot-dip galvanised steel or AISI 316 stainless steel, a compressor and pumping unit to keep the mains water under pressure in a system.

FUNCTIONS AND ADVANTAGES

When the water network does not supply sufficient pressure and/or quantity of water, the MB CAPI pre-autoclave system, consisting of a pressure tank filled 2/3 of water and 1/3 of air and a pressurisation unit, is designed to guarantee the water supply to the highest floors of the buildings. The system guarantees maximum water hygiene, as it is drawn from a closed container under pressure with direct arrival from the water mains without coming into contact with the atmosphere before use.

If the network pressure is sufficient, the system remains stationary, avoiding waste of electricity and the water is renewed inside the tank, flowing towards the users. In this way the water never stagnates avoiding bacterial contamination. If the pressure is insufficient, the system intervenes with a constant flow of water to the electric pump(s) thanks to the inverter system, therefore the inlet pressure from the water mains accumulated in the tank combines with the pressure of the chosen pumping group. In this way it is possible to reduce the installed power and thus obtain economic savings.

composizione Impianto preautoclave da esterno
dettaglio Impianto preautoclave

DIMENSIONAL TABLE MajiBar MB CAPI*

ModelCapacity (L)Compressor (HP)DeHH1H2H3H4H51-8-102-3-20045-6-7-91v1
MB CAPI 1-3003001550155413544574584512451″ 1/41″ 1/41/2″–
MB CAPI 1-5005001650184712746286296215121″ 1/41″ 1/21/2″1″
MB CAPI 1-75075017502133103518968106817181″ 1/42″1/2″1″
MB CAPI 1-10001000185026331035181168126822181″ 1/42″1/2″1″
MB CAPI 2-1500150011,00022951056001100120018001″ 1/42″1/2″1″
MB CAPI 2-200020001,51,00027951056001250135023001″ 1/42″1/2″1″

Pressurised tank technical drawing

Num. ArtDischarge
1Pressurised tank
2-3-2004Power – Use
5-9Visual level indicator
6Pressure gauge
8-11Level switch
7Control instrument
10Safety valve, anti-vacuum valve and automatic air supply

Pre-autoclave system example layout

Art. no.Description
1Pressurised tank
2Pumping group
3Belt driven compressor on base
4Electrical panel for compressor control
5Tank relief safety valve
6Level switch to maintain air/water ratio (to be installed at 2/3 tank height)
7Visual air/water level indicator inside the tank
8Water network inlet with 2” ball valve
9Tank discharge with 1” ball valve
10Pressure booster pumping group delivery
11Pressure gauge
12Compressor pressure switch
Disegno tecnico Impianto preautoclave da esterno
Impianto preautoclave da esterno installazione

Would you like more information on outdoor pre-autoclave system MB CAPI?

Request a callback from one of our consultants specialized in outdoor pre-autoclave systems without obligation.

Share this product line with your collaborators