MF CI-TIC
FIRE-FIGHTING SYSTEM WITH HORIZONTAL PUMPS AND ACCESS BOX
Negative suction head fire-fighting system for underground installation with horizontal centrifugal pumps (END-SUCTION), according to UNI EN 12845:2020 standard. The system includes: water storage tank and integrated firebox complete with stairwell for access from the outside and overt cover box.

TANK AND FIREBOX
- Fire pump room and stairwell located inside the tank
- Tank material: S235JR carbon steel according to UNI 10025.
- Fire pump room material: horizontal and vertical bearing structure made of R60 steel and infill elements made with EI60 insulated panels with A2-s1, d0 fire reaction performance class. Roof covering, also made with insulated panels and covered with corrugated sheet, inclined and complete with rainwater collection.
- Components and accessories according to UNI EN 12845: 2020 and UNI 11292: 2019 fire regulations (see specific section on p. 80). Various options are also available, such as reinforcements to make the system suitable for vehicles and anti-floating devices in the event of groundwater.
- System dimensions as per the following tables. Also available made to measure, and/or modular in dimensions over 100 m3 .
- Access: Single front door made with A1 class fire reaction material, accessible via a straight staircase complete with handrail compliant with UNI 10803 and UNI 10804 standards.
- Tank painting, internal and external: 120 micron thick epoxy bitumen paint.
- Fire pump room floor: non-slip chequered plate
- There is an inspection pit on the tank for the water side and a pit on the pump side, to extract the pumping units in case of maintenance.

MF CI-TIC system access box

MF CI-TBI system interior

Anti-flooding system detail
PUMPING GROUP
Pumping system electrically and hydraulically installed inside the fire pump room in negative suction head installation, the UNI EN 12845:2020 standard in the set-ups with electric and/or motor pumps.


DIMENSION TABLE NEGATIVE SUCTION HEAD FIRE-FIGHTING SYSTEM WITH HORIZONTAL CENTRIFUGAL PUMPS | MajiFire MF CI-TIC*
| Working capacity (m3) | Ø (mm) | L LT from-to (mm) | L S (mm) | L TOT da-a (mm) | Thickness (mm) | Weight from-to** (q) |
| 10 | 3000 | 5000 – 6600 | 2000 | 7000 – 8600 | 6 | 61 – 65 |
| 15 | 3000 | 5000 – 6600 | 2500 | 7500 – 9100 | 6 | 63 – 67 |
| 20 | 3000 | 5000 – 6600 | 3500 | 8500 – 10100 | 6 | 68 – 72 |
| 25 | 3000 | 5000 – 6600 | 4000 | 9000 – 10600 | 6 | 70 – 74 |
| 30 | 3000 | 5000 – 6600 | 5000 | 10000 – 11600 | 6 | 74 – 78 |
| 40 | 3000 | 5000 – 6600 | 6500 | 11500 – 13100 | 6 | 80 – 85 |
| 50 | 3000 | 5000 – 6600 | 8000 | 13000 – 14600 | 6 | 88 – 92 |
| 60 | 3000 | 5000 – 6600 | 9000 | 14000 – 15600 | 6 | 92 – 96 |
| 70 | 3000 | 5000 – 6600 | 10500 | 15500 – 17100 | 6 | 98 – 103 |
| 72 | 3000 | 5000 – 6600 | 11000 | 16000 – 17600 | 6 | 100 – 105 |
| 80 | 3000 | 5000 – 6600 | 12000 | 17000 – 18600 | 6 | 105 – 109 |
| 90 | 3000 | 5000 – 6600 | 13500 | 18500 – 20100 | 6 | 111 – 116 |
| 100 | 3000 | 5000 – 6600 | 15000 | 20000 – 21600 | 6 | 118 – 122 |
* Approximate dimensions to be confirmed upon order
** Empty weight and without pumping group